Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.945
Filtrar
1.
J Neurodev Disord ; 16(1): 6, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429713

RESUMO

BACKGROUND: Angelman syndrome (AS) is a rare neurodevelopmental disorder characterized by severe intellectual disability, little to no expressive speech, visual and motor problems, emotional/behavioral challenges, and a tendency towards hyperphagia and weight gain. The characteristics of AS make it difficult to measure these children's functioning with standard clinical tests. Feasible outcome measures are needed to measure current functioning and change over time, in clinical practice and clinical trials. AIM: Our first aim is to assess the feasibility of several functional tests. We target domains of neurocognitive functioning and physical growth using the following measurement methods: eye-tracking, functional Near-Infrared Spectroscopy (fNIRS), indirect calorimetry, bio-impedance analysis (BIA), and BOD POD (air-displacement plethysmography). Our second aim is to explore the results of the above measures, in order to better understand the AS phenotype. METHODS: The study sample consisted of 28 children with AS aged 2-18 years. We defined an outcome measure as feasible when (1) at least 70% of participants successfully finished the measurement and (2) at least 60% of those participants had acceptable data quality. Adaptations to the test procedure and reasons for early termination were noted. Parents rated acceptability and importance and were invited to make recommendations to increase feasibility. The results of the measures were explored. RESULTS: Outcome measures obtained with eye-tracking and BOD POD met the definition of feasibility, while fNIRS, indirect calorimetry, and BIA did not. The most important reasons for early termination of measurements were showing signs of protest, inability to sit still and poor/no calibration (eye-tracking specific). Post-calibration was often applied to obtain valid eye-tracking results. Parents rated the BOD POD als most acceptable and fNIRS as least acceptable for their child. All outcome measures were rated to be important. Exploratory results indicated longer reaction times to high salient visual stimuli (eye-tracking) as well as high body fat percentage (BOD POD). CONCLUSIONS: Eye-tracking and BOD POD are feasible measurement methods for children with AS. Eye-tracking was successfully used to assess visual orienting functions in the current study and (with some practical adaptations) can potentially be used to assess other outcomes as well. BOD POD was successfully used to examine body composition. TRIAL REGISTRATION: Registered d.d. 23-04-2020 under number 'NL8550' in the Dutch Trial Register: https://onderzoekmetmensen.nl/en/trial/23075.


Assuntos
Síndrome de Angelman , Criança , Humanos , Síndrome de Angelman/complicações , Síndrome de Angelman/diagnóstico , Reprodutibilidade dos Testes , Composição Corporal , Pletismografia/métodos , Impedância Elétrica
2.
Pediatr Allergy Immunol Pulmonol ; 37(1): 7-12, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38484265

RESUMO

Background: Structured light plethysmography (SLP) is a novel light-based method that captures chest wall movements to evaluate tidal breathing. Methods: Thirty-two children who underwent lung surgery were enrolled. Their clinical history was collected along with spirometry and SLP. Results: Median age of surgery was 9 months (interquartile range 4-30). Most frequent diagnosis was congenital pulmonary airway malformation (14/32), then pulmonary sequestration (9/32), tumor (5/32), and bronchogenic cyst (4/32). The most frequent surgical approach was lobectomy (59%), segmentectomy (38%), and complete resection (3%). More than 80% had surgery when younger than 3 years of age. Eight patients had short-term complications (pleural effusion was the most frequent), while long-term effects were reported in 15 patients (19% recurrent cough, 13% thoracic deformities, 13% airway infections, 9% wheezing, 6% reduced exercise tolerance, and 3% columnar deformities). Spirometry was normal in 9/22 patients. Nine patients had a restrictive pattern, while 4 showed a mild bronco-reactivity. Ten patients did not perform spirometry because of young age. SLP revealed the presence of obstructive pattern in 10% of patients (IE50 > 1.88) and showed a significant difference between the two hemithorax in 29% of patients. Discussion: SLP may be a new method to evaluate lung function, without collaboration and radiation exposure, in children who underwent lung resection, also in preschool age.


Assuntos
Pletismografia , Procedimentos Cirúrgicos Pulmonares , Criança , Pré-Escolar , Humanos , Lactente , Pletismografia/métodos , Respiração , Espirometria/métodos , Pulmão/cirurgia
3.
Int. j. clin. health psychol. (Internet) ; 24(1): [100442], Ene-Mar, 2024. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-230383

RESUMO

Background/Objective: Men do not use external condoms for several reasons, which can result in public health problems. One of these is related to Condom-Associated Erectile Problems. This study aimed to examine the sexual arousal response of heterosexual men when using an external condom made of synthetic resin type AT-10. Method: A total of 82 Colombian young men (Mage = 23.17 years, SD = 3.04, age range = 18–30) participated in this experimental study. Two random groups (experimental and control; n = 41 each) were compared. The experimental group used condoms, whereas the control group did not. Fit and feel condom perceptions, initial erectile scores, age, and substance use were controlled for. Erection was measured while viewing a sexual video by using penile plethysmography and subjective arousal. Results: The results, obtained from comparing the experimental group (using pre-erection condoms) with the control group (not using condoms), revealed no significant difference in both subjective and physiological sexual arousal. This suggests that pre-erection condoms do not have an effect on the erectile response. Discussion: More research is needed in this area to provide treatment and clinical interventions or sexual and reproductive education to mitigate the occurrence of sexual dysfunction, unplanned pregnancies, or sexually transmitted infections. Also, research addresses public health issues related to the prevention and/or intervention of sexual risk behaviors and sexual dysfunctions, highlighting their significance in sexual education and clinical practice.(AU)


Assuntos
Humanos , Masculino , Preservativos , Pletismografia , Ereção Peniana , Disfunção Erétil , Colômbia , Psicologia Clínica , Psicologia
4.
PLoS One ; 19(3): e0299252, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38470892

RESUMO

BACKGROUND: Pulmonary function testing by barometric whole-body plethysmography (BWBP) is a long-established and well-accepted, non-invasive investigative procedure in cats. HYPOTHESIS/OBJECTIVES: To evaluate, if different acclimatization times influence the measurement parameters of BWBP in healthy adult cats. ANIMALS: 48 healthy adult cats. METHODS: In the prospective observational study, healthy cats were placed in a measuring chamber and BWBP was performed over 30 minutes. Parameters obtained during the three measurement units of 10 minutes each (T1, T2 and T3) were compared. RESULTS: All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) over the three time periods. From T1-T2, the parameters minute volume per body weight (p<0.001), peak inspiratory flow per body weight (p<0.001), peak expiratory flow per body weight (p = 0.002), pause (p = 0.03), enhanced pause (p = 0.03) and quotient of peak expiratory flow divided by expiratory flow at end expiratory volume plus 50% tidal volume (p = 0.03) changed significantly. From the time interval T2-T3, only respiratory rate (p = 0.02), inspiratory time (p = 0.02), expiratory time (p = 0.04), and relaxation time (p = 0.01) changed significantly. All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) between T1 and T3. Age had a significant influence on all parameters except for peak expiratory flow per body weight and peak inspiratory flow per body weight. The parameters were not influenced by sex. CONCLUSION AND CLINICAL IMPORTANCE: All measurement parameters except tidal volume per body weight were significantly affected by acclimatization time. Controlling for age and sex, there was still a significant influence of acclimatization time on all parameters except for tidal volume per body weight. Standardization of the acclimatization time for future studies would be appropriate in order to maintain comparability.


Assuntos
Pletismografia , Gatos , Animais , Pletismografia Total/métodos , Pletismografia Total/veterinária , Testes de Função Respiratória/métodos , Volume de Ventilação Pulmonar , Peso Corporal
5.
Clin Transl Sci ; 17(2): e13735, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38344891

RESUMO

Buloxibutid (also known as C21) is a potent and selective angiotensin II type 2 receptor (AT2R) agonist, in development for oral treatment of fibrotic lung disease. This phase I, open-label, pharmacodynamic study investigated vascular effects of buloxibutid in five healthy male volunteers. Subjects were administered intra-arterial infusions of buloxibutid for 5 min in ascending doses of 3, 10, 30, 100, and 200 µg/min, infused sequentially in the forearm. Infusions of sodium nitroprusside (SNP) solution in doses of 0.8-3.2 µg/min were administered as a positive control. Forearm blood flow (FBF) was measured by venous occlusion plethysmography. Safety and tolerability of intra-arterial administrations of buloxibutid were evaluated. Following infusion of buloxibutid in doses of 3-200 µg/min, the range of increase in FBF was 27.8%, 17.2%, 37.0%, 28.5%, and 60.5%, compared to the respective baseline. The largest increase was observed in the highest dose group. Infusions of SNP as a positive control, increased FBF 230-320% compared to baseline. Three adverse events (AEs) of mild intensity, not related to buloxibutid or SNP, were reported for two subjects. Two of these AEs were related to study procedures. There were no clinically relevant changes in arterial blood pressure during the study period. Intra-arterial infusion of buloxibutid in low, ascending doses increased FBF, indicating that buloxibutid may be effective in conditions associated with endothelial dysfunction. Venous occlusion plethysmography was found to be a useful method to explore pharmacodynamic vascular effects of novel AT2R agonists, while avoiding systemic adverse effects.


Assuntos
Pletismografia , Receptor Tipo 2 de Angiotensina , Humanos , Masculino , Nitroprussiato/efeitos adversos , Pletismografia/métodos , Antebraço/irrigação sanguínea , Fluxo Sanguíneo Regional , Vasodilatação
6.
Artigo em Inglês | MEDLINE | ID: mdl-38265049

RESUMO

AIM: To determine the validity of bioelectrical impedance analysis (BIA) in quantifying fat-free mass (FFM) compared to air-displacement plethysmography (ADP) in patients with a motor neurone disease (MND). METHODS: FFM of 140 patients diagnosed with MND was determined by ADP using the BodPod (i.e. the gold standard), and by BIA using the whole-body Bodystat. FFM values were translated to predicted resting energy expenditure (REE); the actual REE was measured using indirect calorimetry, resulting in a metabolic index. Validity of the BIA compared to the ADP was assessed using Bland-Altman analysis and Pearson's r. To assess the clinical relevance of differences, we evaluated changes in metabolic index and in individualized protein demand. RESULTS: Despite the high correlation between ADP and BIA (r = 0.93), averaged across patients, the assessed mean fat-free mass was 51.7 kg (± 0.9) using ADP and 54.2 kg (± 1.0) using BIA. Hence, BIA overestimated fat-free mass by 2.5 kg (95% CI 1.8-3.2, p < 0.001). Clinically, an increased metabolic index would be more often underdiagnosed in patients with MND using BIA (31.4% according to BIA versus 44.2% according to ADP, p = 0.048). A clinically relevant overestimation of ≥ 15 g in protein demand was observed for 4 (2.9%) patients using BIA. CONCLUSIONS: BIA systematically overestimates FFM in patients with MND. Although the differences are limited with ADP, underscoring the utility of BIA for research, overestimation of fat-free mass may have consequences for clinical decision-making, especially when interest lies in determining the metabolic index.


Assuntos
Esclerose Amiotrófica Lateral , Doença dos Neurônios Motores , Humanos , Composição Corporal , Estudos Transversais , Pletismografia/métodos , Impedância Elétrica , Reprodutibilidade dos Testes , Doença dos Neurônios Motores/diagnóstico
7.
Mil Med ; 189(1-2): e136-e140, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-37285305

RESUMO

Military tactical athletes face the unique task of performing physically demanding occupational duties, often while wearing body armor. Forced vital capacity and forced expiratory volume measured using spirometry have been shown to decrease, while wearing plate-carrier style body armor, little is known about the comprehensive effects of wearing body armor on pulmonary function, including lung capacities. Further, the effects of loaded body armor vs. unloaded on pulmonary function are also unknown. Therefore, this study examined how loaded and unloaded body armor affects pulmonary function. Twelve college-aged males performed spirometry and plethysmography under three conditions (basic athletic attire [CNTL], unloaded plate carrier [UNL], and loaded plate carrier [LOAD]). Compared to CNTL, LOAD and UNL conditions significantly reduced functional residual capacity by 14% and 17%, respectively. Compared with CNTL, LOAD condition also showed a small but statistically significant lowered forced vital capacity (P = .02, d = 0.3), a 6% lower total lung capacity (P < .01, d = 0.5), and lowered maximal voluntary ventilation (P = .04, d = 0.4). A loaded plate-carrier style body armor exerts a restrictive effect on total lung capacity, and both loaded and unloaded body armor affects functional residual capacity, which could impact breathing mechanics during exercise. Resulting endurance performance decreases may need to be factored based on the style and loading of body armor, especially for longer-duration operations.


Assuntos
Exercício Físico , Pulmão , Masculino , Humanos , Adulto Jovem , Capacidade Vital , Volume Expiratório Forçado , Pletismografia , Espirometria
8.
J Clin Monit Comput ; 38(1): 121-130, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37715858

RESUMO

The purpose of this study was to evaluate the feasibility and accuracy of remote Video Plethysmography (VPPG) for contactless measurements of blood pressure (BP) and heart rate (HR) in adult surgical patients in a hospital setting. An iPad Pro was used to record a 1.5-minute facial video of the participant's face and VPPG was used to extract vital signs measurements. A standard medical device (Welch Allyn) was used for comparison to measure BP and HR. Trial registration: NCT05165381. Two-hundred-sixteen participants consented and completed the contactless BP and HR monitoring (mean age 54.1 ± 16.8 years, 58% male). The consent rate was 75% and VPPG was 99% successful in capturing BP and HR. VPPG predicted SBP, DBP, and HR with a measurement bias ± SD, -8.18 ± 16.44 mmHg, - 6.65 ± 9.59 mmHg, 0.09 ± 6.47 beats/min respectively. Pearson's correlation for all measurements between VPPG and standard medical device was significant. Correlation for SBP was moderate (0.48), DBP was weak (0.29), and HR was strong (0.85). Most patients were satisfied with the non-contact technology with an average rating of 8.7/10 and would recommend it for clinical use. VPPG was highly accurate in measuring HR, and is currently not accurate in measuring BP in surgical patients. The VPPG BP algorithm showed limitations in capturing individual variations in blood pressure, highlighting the need for further improvements to render it clinically effective across all ranges. Contactless vital signs monitoring was well-received and earned a high satisfaction score.


Assuntos
Assistência Perioperatória , Pletismografia , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Pressão Sanguínea/fisiologia , Frequência Cardíaca
9.
J Clin Monit Comput ; 38(1): 47-55, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37698697

RESUMO

The accurate recording of respiratory rate (RR) without contact is important for patient care. The current methods for RR measurement such as capnography, pneumography, and plethysmography require patient contact, are cumbersome, or not accurate for widespread clinical use. Video Plethysmography (VPPG) is a novel automated technology that measures RR using a facial video without contact. The objective of our study was to determine whether VPPG can feasibly and accurately measure RR without contact in surgical patients at a clinical setting. After research ethics approval, 216 patients undergoing ambulatory surgery consented to the study. Patients had a 1.5 min video of their faces taken via an iPad preoperatively, which was analyzed using VPPG to obtain RR information. The RR prediction by VPPG was compared to 60-s manual counting of breathing by research assistants. We found that VPPG predicted RR with 88.8% accuracy and a bias of 1.40 ± 1.96 breaths per minute. A significant and high correlation (0.87) was observed between VPPG-predicted and manually recorded RR. These results did not change with the ethnicity of patients. The success rate of the VPPG technology was 99.1%. Contactless RR monitoring of surgical patients at a hospital setting using VPPG is accurate and feasible, making this technology an attractive alternative to the current approaches to RR monitoring. Future developments should focus on improving reliability of the technology.


Assuntos
Pletismografia , Taxa Respiratória , Humanos , Reprodutibilidade dos Testes , Monitorização Fisiológica/métodos , Respiração
10.
Artigo em Inglês | MEDLINE | ID: mdl-38082687

RESUMO

This study presents fingertip strain plethysmography (SPG) as a visual trace of cardiac cycles in peripheral vessels. The setup includes a small, sensitive MEMS strain sensor attached to the fingertip to capture the pulsatile vibrations corresponding to cardiac cycles. SPG is evaluated on 10 healthy subjects for the estimation of heart rate (HR) and heart rate variability (HRV), as well as heartbeat-derived respiratory rate (RR) which is an HRV parameter. The estimated parameters are compared with a simultaneously-recorded electrocardiogram (ECG) for HR and HRV, and an inertial sensor placed on the chest wall for RR. Bland-Altman analyses suggest small estimation biases of 0.03 beats-per-minute (BPM) and 0.38 ms for HR and HRV respectively, demonstrating excellent agreement between fingertip SPG and ECG. The average estimation accuracies of 99.88% (± 0.04), 96.43% (± 1.44), and 92.64% (± 2.30) for HR, HRV, and RR respectively, prove the reliability of SPG for hemodynamic monitoring.Clinical Relevance- Conventional plethysmography sensors are either cumbersome or susceptible to skin color. This effort is a fundamental step towards the augmentation of conventional methods, thus ensuring stable, clinical-grade hemodynamic monitoring.


Assuntos
Fotopletismografia , Vibração , Humanos , Frequência Cardíaca/fisiologia , Reprodutibilidade dos Testes , Fotopletismografia/métodos , Pletismografia
11.
Artigo em Inglês | MEDLINE | ID: mdl-38083056

RESUMO

Given the gap between the crucial role of measuring arterial stiffness in cardiovascular disease prevention and the lack of a technology for frequent/continuous measurement to assess it without an operator, we have developed a wearable accelerometer-based system. It estimates local stiffness metrics (Ep, ß, and AC) by employing a one-point patient-specific calibration on the features of acceleration plethysmogram (APG) signal. An in-vivo study on 12 subjects was conducted (a) to select suitable ones from the host features on which the calibration could be applied and (b) to assess the feasibility of reliably estimating the stiffness metrics post-exercise when calibrated prior. The acquired APG signals were found to be reliable (SNR > 38 dB) and repeatable (CoV < 10 %). By examining a correlation matrix, it was found that (a-b)/(a"-b") is a potential feature of consideration for calibration against the stiffness. Due to exercise intervention, the local stiffness metrics have physiologically perturbed by a significant amount (p < 0.05), as observed from the reference measurements. Estimated Ep was found to have statistically significant and strong correlation (r = 0.761, p < 0.05) with actual Ep value, whereas statistically significant and moderate correlation were found with estimated ß (r = 0.682, p < 0.05) and estimated AC (r = 0.615, p < 0.05) with their respective actual measures. The system demonstrated its ability to estimate post-exercise stiffness metrics using the baseline calibration, even when subject to significant physiological changes.Clinical Relevance- This study reveals the potential of the developed wearable system to be used for continuous stiffness estimation even in the presence of hemodynamic perturbations.


Assuntos
Rigidez Vascular , Dispositivos Eletrônicos Vestíveis , Humanos , Rigidez Vascular/fisiologia , Projetos Piloto , Pletismografia , Acelerometria
12.
Sensors (Basel) ; 23(24)2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-38139582

RESUMO

Respiratory rate monitoring is fundamental in clinical settings, and the accuracy of measurement methods is critical. This study aimed to develop and validate methods for assessing respiratory rate and the duration leof respiratory cycle phases in different body positions using optoelectronic plethysmography (OEP) based on a motion capture video system. Two analysis methods, the summation method and the triangle method were developed. The study focused on determining the optimal number of markers while achieving accuracy in respiratory parameter measurements. The results showed that most analysis methods showed a difference of ≤0.5 breaths per minute, with R2 ≥ 0.94 (p < 0.001) compared to spirometry. The best OEP methods for respiratory rate were the abdominal triangles and the sum of abdominal markers in all body positions. The study explored inspiratory and expiratory durations. The research found that 5-9 markers were sufficient to accurately determine respiratory time components in all body positions, reducing the marker requirements compared to previous studies. This interchangeability of OEP methods with standard spirometry demonstrates the potential of non-invasive methods for the simultaneous assessment of body segment movements, center of pressure dynamics, and respiratory movements. Future research is required to improve the clinical applicability of these methods.


Assuntos
Captura de Movimento , Taxa Respiratória , Respiração , Pletismografia/métodos , Espirometria
13.
J Physiol ; 601(21): 4767-4806, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37786382

RESUMO

Comprehensive and accurate analysis of respiratory and metabolic data is crucial to modelling congenital, pathogenic and degenerative diseases converging on autonomic control failure. A lack of tools for high-throughput analysis of respiratory datasets remains a major challenge. We present Breathe Easy, a novel open-source pipeline for processing raw recordings and associated metadata into operative outcomes, publication-worthy graphs and robust statistical analyses including QQ and residual plots for assumption queries and data transformations. This pipeline uses a facile graphical user interface for uploading data files, setting waveform feature thresholds and defining experimental variables. Breathe Easy was validated against manual selection by experts, which represents the current standard in the field. We demonstrate Breathe Easy's utility by examining a 2-year longitudinal study of an Alzheimer's disease mouse model to assess contributions of forebrain pathology in disordered breathing. Whole body plethysmography has become an important experimental outcome measure for a variety of diseases with primary and secondary respiratory indications. Respiratory dysfunction, while not an initial symptom in many of these disorders, often drives disability or death in patient outcomes. Breathe Easy provides an open-source respiratory analysis tool for all respiratory datasets and represents a necessary improvement upon current analytical methods in the field. KEY POINTS: Respiratory dysfunction is a common endpoint for disability and mortality in many disorders throughout life. Whole body plethysmography in rodents represents a high face-value method for measuring respiratory outcomes in rodent models of these diseases and disorders. Analysis of key respiratory variables remains hindered by manual annotation and analysis that leads to low throughput results that often exclude a majority of the recorded data. Here we present a software suite, Breathe Easy, that automates the process of data selection from raw recordings derived from plethysmography experiments and the analysis of these data into operative outcomes and publication-worthy graphs with statistics. We validate Breathe Easy with a terabyte-scale Alzheimer's dataset that examines the effects of forebrain pathology on respiratory function over 2 years of degeneration.


Assuntos
Respiração , Software , Animais , Camundongos , Humanos , Estudos Longitudinais , Pletismografia
14.
Indian Pediatr ; 60(12): 985-990, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37700583

RESUMO

BACKGROUND: Small for gestational age (SGA) neonates are prone to growth deficits in early life, which may be associated with later life metabolic abnormalities. OBJECTIVES: To compare anthropometry and body composition using air-displacement plethysmography (ADP) in term SGA and appropriate for gestational age (AGA) neonates, and assess if sexual dimorphism existed in estimates of body composition. STUDY DESIGN: Cross-sectional analytical study. PARTICIPANTS: 413 term neonates (91 SGA and 322 AGA) at birth (≤7days). METHODS: Neonatal anthropometry and body composition were measured using ADP. Length corrected fat mass index (FMI) and fat free mass index (FFMI) were calculated. OUTCOME: Anthropometry and body composition estimates of SGA and AGA neonates, segregated by sex. RESULTS: The mean (SD) birth weight of SGA and AGA neonates was 2.5 (0.2) kg and 3.1 (0.3) kg, respectively. SGA neonates had significantly lower % body fat (BF) (2.0%), fat mass (94.4 g), fat free mass (FFM) (349.7 g), FMI (0.34 kg/m2), and FFMI (0.76 kg/m2), but higher %FFM (2.0%) compared to AGA neonates (P<0.001). Males had significantly higher %FFM [91.2 (3.1) vs 90.2 (3.5); P=0.001], FFM [2604 (280) vs 2442 (233) g; P<0.001], and FFMI [11.1 (0.8) vs 10.8 (0.8) kg/m2; P=0.005], but lower % BF [8.8 (3.1) vs 9.8 (3.5); P=0.001] and FMI [1.1(0.4) vs 1.2 (0.5) kg/m2; P=0.008], compared to females. CONCLUSIONS: Accurate estimates of body composition in neonates at birth suggest significantly lower body fat and fat free mass in SGA compared to AGA, with sexual dimorphism.


Assuntos
Composição Corporal , Recém-Nascido Pequeno para a Idade Gestacional , Recém-Nascido , Masculino , Feminino , Humanos , Idade Gestacional , Estudos Transversais , Antropometria , Peso ao Nascer , Pletismografia
15.
Sensors (Basel) ; 23(18)2023 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-37765988

RESUMO

BACKGROUND: Elevated nocturnal blood pressure (BP) is a risk factor for cardiovascular disease (CVD) and mortality. Cuffless BP assessment aided by machine learning could be a desirable alternative to traditional cuff-based methods for monitoring BP during sleep. We describe a machine-learning-based algorithm for predicting nocturnal BP using single-channel fingertip plethysmography (PPG) in healthy adults. METHODS: Sixty-eight healthy adults with no apparent sleep or CVD (53% male), with a median (IQR) age of 29 (23-46 years), underwent overnight polysomnography (PSG) with fingertip PPG and ambulatory blood pressure monitoring (ABPM). Features based on pulse morphology were extracted from the PPG waveforms. Random forest models were used to predict night-time systolic blood pressure (SBP) and diastolic blood pressure (DBP). RESULTS: Our model achieved the highest out-of-sample performance with a window length of 7 s across window lengths explored (60 s, 30 s, 15 s, 7 s, and 3 s). The mean absolute error (MAE ± STD) was 5.72 ± 4.51 mmHg for SBP and 4.52 ± 3.60 mmHg for DBP. Similarly, the root mean square error (RMSE ± STD) was 6.47 ± 1.88 mmHg for SBP and 4.62 ± 1.17 mmHg for DBP. The mean correlation coefficient between measured and predicted values was 0.87 for SBP and 0.86 for DBP. Based on Shapley additive explanation (SHAP) values, the most important PPG waveform feature was the stiffness index, a marker that reflects the change in arterial stiffness. CONCLUSION: Our results highlight the potential of machine learning-based nocturnal BP prediction using single-channel fingertip PPG in healthy adults. The accuracy of the predictions demonstrated that our cuffless method was able to capture the dynamic and complex relationship between PPG waveform characteristics and BP during sleep, which may provide a scalable, convenient, economical, and non-invasive means to continuously monitor blood pressure.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão Sanguínea , Doenças Cardiovasculares , Hipertensão , Aprendizado de Máquina , Pletismografia , Sono , Adulto Jovem
16.
Sensors (Basel) ; 23(15)2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37571742

RESUMO

The identification of respiratory patterns based on the movement of the chest wall can assist in monitoring an individual's health status, particularly those with neuromuscular disorders, such as hemiplegia and Duchenne muscular dystrophy. Thoraco-abdominal asynchrony (TAA) refers to the lack of coordination between the rib cage and abdominal movements, characterized by a time delay in their expansion. Motion capture systems, like optoelectronic plethysmography (OEP), are commonly employed to assess these asynchronous movements. However, alternative technologies able to capture chest wall movements without physical contact, such as RGB digital cameras and time-of-flight digital cameras, can also be utilized due to their accessibility, affordability, and non-invasive nature. This study explores the possibility of using a single RGB digital camera to record the kinematics of the thoracic and abdominal regions by placing four non-reflective markers on the torso. In order to choose the positions of these markers, we previously investigated the movements of 89 chest wall landmarks using OEP. Laboratory tests and volunteer experiments were conducted to assess the viability of the proposed system in capturing the kinematics of the chest wall and estimating various time-related respiratory parameters (i.e., fR, Ti, Te, and Ttot) as well as TAA indexes. The results demonstrate a high level of agreement between the detected chest wall kinematics and the reference data. Furthermore, the system shows promising potential in estimating time-related respiratory parameters and identifying phase shifts indicative of TAA, thus suggesting its feasibility in detecting abnormal chest wall movements without physical contact with a single RGB camera.


Assuntos
Parede Torácica , Humanos , Estudos de Viabilidade , Fenômenos Biomecânicos , Mecânica Respiratória , Respiração , Pletismografia/métodos
17.
Nutrition ; 114: 112133, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37499562

RESUMO

OBJECTIVES: The aim of this study is to develop predictive body fat mass models, one for newborns and one for infants, using air displacement plethysmography as a reference method. METHODS: The study was carried out with 125 newborns (1-5 d of age) and 71 infants (≥3-6 mo). The stepwise method was used to estimate the final model from the predictors of sex, weight, length, triceps skinfold, waist circumference, mean arm circumference, and gestational age. The quality of the models was evaluated by the determination coefficient, variance inflation factor, and residual analysis. The paired t test and Bland-Altman plot were used to assess the agreement between observed and estimated values. RESULTS: The final model for newborns was - 0.76638 + 0.2512 * weight (kg) + 0.0620 * PCT (mm) + 0.0754 * gender (R² = 70%) and the final model for infants: -2.22748 + 0.4928 * weight (kg) + 0.0737 * TSF (mm) + 0.2647 * gender (R² = 84%). CONCLUSIONS: This work determined equations to estimate the BFM of term newborns and infants. The models can be used in clinical practice, especially in health units without access to technologies for measuring body composition, adding important information for nutritional monitoring.


Assuntos
Tecido Adiposo , Composição Corporal , Humanos , Recém-Nascido , Lactente , Idoso , Peso Corporal , Antropometria/métodos , Idade Gestacional , Pletismografia/métodos
18.
J Pediatr Gastroenterol Nutr ; 77(4): 553-557, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37496142

RESUMO

BACKGROUND: The nutritional status of children with intestinal failure (IF) can be difficult to determine using body weight and currently available anthropometric techniques. Air displacement plethysmography (ADP) is a noninvasive measure of whole-body composition that measures body mass and volume, with a calculation of percent body fat (%BF) and fat-free mass (FFM) that may be useful during the provision of specialized nutrition. OBJECTIVES: To evaluate the validity and feasibility of measuring body composition in children with IF using ADP compared with deuterium dilution (DD), as well as secondarily with other measures of body composition, namely bioelectrical impedance analysis (BIA), dual-energy X-ray absorptiometry (DXA), and four-site skinfold anthropometry. METHODS: We conducted a prospective cohort study of 18 children recruited through the Center for Advanced Intestinal Rehabilitation at Boston Children's Hospital. Patients 2-17 years of age with IF dependent on parenteral nutrition (PN) for more than 90 days were included. Spearman rank correlation and Bland-Altman limits of agreement (LOA) analysis were used to compare ADP to 4 alternative measures of body composition. RESULTS: Eighteen children with IF, median age 7.1 [interquartile range (IQR) 5.4-9.3] years, 9 female (50%), and median residual bowel length 31 (IQR 22-85) cm were enrolled. Median PN energy intake was 46 (IQR 39-49) kcal/kg/day. Incomplete bladder emptying lead to invalid measures of DD in 4 subjects. Spearman correlation coefficients for %BF were low to moderate between ADP and DD ( r = 0.29), DXA ( r = 0.62), BIA ( r = 0.50), and skinfold ( r = 0.40). Correlations for FFM were high between ADP and these other measures (range 0.95-0.98). Comparing ADP with DD and skinfold measures, Bland-Altman analysis showed small mean bias (-1.9 and +1.5 kg) and acceptable 95% LOA ranges (10.7 and 22.9 kg), respectively, with larger bias (-10.7 and -7.7 kg) and LOA ranges (38.7 and 45.2 kg) compared to DXA and BIA. %BF by ADP and skinfold thickness were moderately correlated ( r = 0.43) with low bias (-0.2%) but very wide LOA (25.7%). CONCLUSIONS: Body composition via ADP is feasible and valid in children with IF as a measure of FFM but appears less suitable for the measurement of %BF. The technique holds promise as a noninvasive measure of body composition to assess the efficacy of nutritional, medical, and surgical interventions.


Assuntos
Insuficiência Intestinal , Humanos , Criança , Feminino , Pré-Escolar , Lactente , Estudos Prospectivos , Pletismografia/métodos , Impedância Elétrica , Composição Corporal , Tecido Adiposo , Absorciometria de Fóton/métodos , Reprodutibilidade dos Testes
19.
Front Public Health ; 11: 1164556, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37469700

RESUMO

Background: Accurate assessment of body composition (BC) is important to investigate the development of childhood obesity. A bioelectrical impedance analysis (BIA) device is portable and inexpensive compared with air displacement plethysmography (ADP) for the assessment of BC and is widely used in children. However, studies of the effectiveness of BIA are few and present different results, especially in pediatric populations. The aim of this study was to evaluate the agreement between BIA and ADP for estimating BC. Methods: The BC of 981 Chinese children (3-5 years) was measured using the BIA device (SeeHigher BAS-H, China) and ADP (BOD POD). Results: Our results showed that BIA underestimated fat mass (FM) and overestimated fat-free mass (FFM) in normal weight children (P < 0.05), but the opposite trend was shown in children with obesity (P < 0.05). The agreement between FM and FFM measured by the two methods was strong (CCC > 0.80). The linear regression equation of 5-year-old children was constructed. Conclusion: The SeeHigher BAS-H multi-frequency BIA device is a valid device to evaluate BC in Chinese preschool children compared with ADP (BOD POD), especially in 5-year-old children or children with obesity. Further research is needed to standardize the assessment of BC in children.


Assuntos
Obesidade Pediátrica , Pletismografia , Criança , Humanos , Pré-Escolar , Impedância Elétrica , Pletismografia/métodos , Composição Corporal , Modelos Lineares
20.
Clin Nutr ; 42(9): 1588-1594, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37478812

RESUMO

BACKGROUND & AIMS: Air-Displacement-Plethysmography (ADP) by BOD POD is widely used for body fat assessment in children. Although validated in healthy subjects, studies about use in pediatric patients are lacking. We evaluated user experience and usability of ADP measurements with the BOD POD system in healthy children and pediatric and young adult patients. METHODS: Using the experiences of seven cohort studies, which included healthy children and patients aged 2-22 years, we retrospectively evaluated the user experience with the User Experience Questionnaire (UEQ) (n = 13) and interviews (n = 7). Technical performance was studied using the quality control data collected by the ADP-system. RESULTS: From 2016 to 2022, 1606 measurements were scheduled. BOD POD was mostly rated 'user-friendly', with a generally neutral evaluation on all scales of the UEQ. However, questionable reliability and validity of the results were frequently (86%) reported. We found a high technical failure-rate of the device, predominantly in stability (17%) and accuracy of the measurement (12%), especially in the 'pediatric option' for children aged <6 years. Measurement failure-rate was 38%, mostly due to subject's fear or device failure, especially in young and lean children, and in children with physical and/or intellectual disabilities. CONCLUSION: We conclude that ADP by BOD POD in children and young adults is non-invasive and user-friendly. However, in specific pediatric populations, BOD POD has several limitations and high (technical) failure-rates, especially in young children with aberrant body composition. We recommend caution when interpreting body composition results of pediatric patients as assessed with BOD POD using the current default settings.


Assuntos
Composição Corporal , Pletismografia , Humanos , Adulto Jovem , Criança , Pré-Escolar , Reprodutibilidade dos Testes , Estudos Retrospectivos , Pletismografia/métodos , Tecido Adiposo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...